Category
Pico Laser Machine
Pelvic Floor Muscle Repair System
6D Laser
360 degree freezing
TEREPIA magnetica
HIFU Skin Tightening and Lifting System
CTL Cryolipolysis series
Cryo Lipolaser
3S Cryolipolysis Body Slimming
Coolsculpting for body shape
Lipo Laser
RF Thermage
4D 528 Diodes Lipolaser Slimming Machine
IPL& E-LIGHT
ND Yag Laser
810nm Diode laser Hair Removal Machine
Pressotherapy Lymph Drainage
Body Slimming Equipment
Cavitation Vacuum RF beauty Equipment
PDT and LED Massage Machine
540 pins Dermaroller
192 pins Dermaroller Skin nusring system
Hydrodermabrasion and microdermabrasion machine
Fractional CO2 laser Machine
Ultra HIFU Slimming Liposonix
Icewind cooling system
1060nm body slimming machine
Hair Regrowth Machine
Velashape Machine
Derma Roller Dr. Pen
Shock Wave Machine
Microneedle RF Equipment
Emsculpt Body Slimming Machine
Contact Us
|
Fractional CO2 Laser Machine
Description:
Laser Type CO2 Wavelength: 10600nm Beam Delivery 7-joint arm Maximum Output Power: 15W/30W/40W Optical Beam Quality TEM Spot Size 0.12-1.25mm (Adjustable) Power of the Aiming Beam <5mW Aiming Beam 635nm Scanning Mode Randomized Scanning Laser Operating Mode UltraPulse fractional/normal Cooling Air Cooling Pulse Energy 10mj~200mj (every stepping:2mj) Spot Pattern Triangle/Square/Rectangle/Rhombus Pulse Interval 1ms~100ms (every stepping:1mj) Scan Area 10mmx10mm,20mmx20mm,30mmx30mm Working Mode Continuous operation Spot Density 36 spots/cm,144 spots/cm,576spots/cm,with intermittent loading Power Supply AC 220V 50Hz/AC 110V 60Hz Net Weight 45KGS Gross Weight 60KGS Dimensions (after packaged) 760mmx455mmx975mm
Laser Type CO2 Wavelength: 10600nm Beam Delivery 7-joint arm Maximum Output Power: 15W/30W/40W Optical Beam Quality TEM Spot Size 0.12-1.25mm (Adjustable) Power of the Aiming Beam <5mW Aiming Beam 635nm Scanning Mode Randomized Scanning Laser Operating Mode UltraPulse fractional/normal Cooling Air Cooling Pulse Energy 10mj~200mj (every stepping:2mj) Spot Pattern Triangle/Square/Rectangle/Rhombus Pulse Interval 1ms~100ms (every stepping:1mj) Scan Area 10mmx10mm,20mmx20mm,30mmx30mm Working Mode Continuous operation Spot Density 36 spots/cm,144 spots/cm,576spots/cm,with intermittent loading Power Supply AC 220V 50Hz/AC 110V 60Hz Net Weight 45KGS Gross Weight 60KGS Dimensions (after packaged) 760mmx455mmx975mm CO2 Fractional Laser beauty equipment Treatment Theory Fractional laser light penetrates the skin with tiny thermal channels through the random scanning, creating an ablative and thermal effecton only channels (a micro-injury) without damaging the surrounding tissue. The tissue surrounding the micro-injury sites (about 15-20% of the treatment area) starts the process of healing. As collagen remodels, skin tightened, scars improved and pigmented lesions removed.
Application 1.Application Range of Fractional treatment handpiece a.Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks. b.Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid; c.Reconstruction of photoaging skin.
2.Application Range of Incision Handpiece a.Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery b.In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
BR60 Advantages Two modes of laser energy output are selective: UltraPulse Fractional and normal modes Adopt COHERENT RF-excited laser system enables the output quality more stable, more uniform, more consistent, (compared to ordinary CO2 laser installed with glass tubes) Healing zone volume is adjustable, namely the volume of spots is adjustable in a certain healing zone. Therapists could adjust the spot density upon skin type, lesion parts and effectiveness requirement of different patients Various spot volumes are suitable for different area of the body which maximally avoid the side-effect that result from the overlap of the spot, reduce the pain during the treatment, satisfy different therapiests unique request. 8.4 TFT touch LCD, Reserved entry access for laser room ensures a safe treatment Comparing with existing traditional CO2 Sealed Glass Laser, RF excited CO2 lasts nearly permanently, therefore it deserves a higher initial cost which will be offset by a much lower total of ownership.
Parameter Laser Type CO2 Wavelength 10600nm Beam Delivery 7-joint arm Maximum Output Power: 15W/30W/40W Optical Beam Quality TEM Spot Size 0.12-1.25mm (Adjustable) Power of the Aiming Beam <5mW Aiming Beam 635nm Scanning Mode Randomized Scanning Laser Operating Mode UltraPulse fractional/normal Cooling Air Cooling Pulse Energy 10mj~200mj (every stepping:2mj) Spot Pattern Triangle/Square/Rectangle/Rhombus Pulse Interval 1ms~100ms (every stepping:1mj) Scan Area 10mmx10mm,20mmx20mm,30mmx30mm Working Mode Continuous operation Spot Density 36 spots/cm,144 spots/cm,576spots/cm,with intermittent loading
Power Supply AC 220V 50Hz/AC 110V 60Hz Net Weight 45KGS Gross Weight 60KGS Dimensions (after packaged) 760mmx455mmx975mm TAG: #Fractional CO2 laser, #CO2 wrinkles removal, #CO2 skin pigmentation removal, #CO2 laser acne removal