Category
Pico Laser Machine
Pelvic Floor Muscle Repair System
6D Laser
360 degree freezing
TEREPIA magnetica
HIFU Skin Tightening and Lifting System
CTL Cryolipolysis series
Cryo Lipolaser
3S Cryolipolysis Body Slimming
Coolsculpting for body shape
Lipo Laser
RF Thermage
4D 528 Diodes Lipolaser Slimming Machine
IPL& E-LIGHT
ND Yag Laser
810nm Diode laser Hair Removal Machine
Pressotherapy Lymph Drainage
Body Slimming Equipment
Cavitation Vacuum RF beauty Equipment
PDT and LED Massage Machine
540 pins Dermaroller
192 pins Dermaroller Skin nusring system
Hydrodermabrasion and microdermabrasion machine
Fractional CO2 laser Machine
Ultra HIFU Slimming Liposonix
Icewind cooling system
1060nm body slimming machine
Hair Regrowth Machine
Velashape Machine
Derma Roller Dr. Pen
Shock Wave Machine
Microneedle RF Equipment
Emsculpt Body Slimming Machine
Contact Us
|
Velashape Cryolipolysis Cavitation RF Lipolaser
Description:
Cryolipolysis system Specification 1.Input voltage: AC110V/220V 50-60Hz 2.Power consumption:<400w 3.Screen:8 inch wide color touch screen 4.Cooling device output temperature:5 to -16°C 5. output Vacuum pressure: 0-110KPa 6.Cooling liquid: pure water 7.Default time: 0-60min 8.Fuse size: F3AL250V 9. Ambient temperature: 5°C-+42°C 10.Relative humidity: ≤85% 11.Atmospheric pressure: 80KPa-106KPa 12. 104 diodes, Mitsubishi with 100mw/300mw, dual wave length; 13. 660nm and 980nm real Mitsubishi diodes ; 14. Lipolaser pads: 4 big ones each with 24 diodes, 2 small ones each with 4 diodes, 15.N/W: 35KG, GW.:55KGS 16. Cavitation with 28KHz, out power with 80w; 17. CET Multipolar RF with 5Mhz; 18. Vacuum velashape with 100KPa, Vacuum, Four RF with PDT three in one
Cryolipolysis system Specification 1.Input voltage: AC110V/220V 50-60Hz 2.Power consumption:<400w 3.Screen:8 inch wide color touch screen 4.Cooling device output temperature:5 to -16°C 5. output Vacuum pressure: 0-110KPa 6.Cooling liquid: pure water 7.Default time: 0-60min 8.Fuse size: F3AL250V 9. Ambient temperature: 5°C-+42°C 10.Relative humidity: ≤85% 11.Atmospheric pressure: 80KPa-106KPa 12. 104 diodes, Mitsubishi with 100mw/300mw, dual wave length; 13. 660nm and 980nm real Mitsubishi diodes ; 14. Lipolaser pads: 4 big ones each with 24 diodes, 2 small ones each with 4 diodes, 15.N/W: 35KG, GW.:55KGS 16. Cavitation with 28KHz, out power with 80w; 17. CET Multipolar RF with 5Mhz; 18. Vacuum velashape with 100KPa, Vacuum, Four RF with PDT three in one Cryolipolysis + 104 diodes lipolaser How does Cryolipo™ work ? One or two suction and cooling heads (independently controlled) with large surface areas are placed on the areas to be treated. The Cryolipo™ cooling heads generate a vacuum that temporarily decreases blood flow to the treated area, immobilizing the fat tissue, and isolating the treated area from surrounding tissue. Low temperature (0° C to - 5 °C depending on the thickness of the fat tissue (which is measured before each treatment with special calipers), is then applied to the area in a controlled process, ‘freezing’ the localized area for a controlled period of time. Once the cooling procedure is completed, the fat cells crystallize and after melting the broken fat cells release the lipids into the lymphatic system, which will gradually eliminate them by natural metabolism. Skin isn’t damaged, but subcutaneous fat, which is more sensitive to targeted cold, begins a two to three month long dissolution after each Cryolipo™ procedure. Cryolipo™ treatment's results can be enhanced by using Vela shape, Lipolaser and RF sessions in between each treatment, which helps by increasing the breakage of the broken fat cells, lymph drainage and skin tightening. The procedure is performed in a licensed and authorized Cryoclinic and supervised by a trained professional. There is no anesthesia or recovery time needed. After the Cryolipo™ treatment, clients may immediately return to their normal activities including work and exercise. Fat cells are more sensitive to low temperatures than surrounding tissues. This makes it possible to crystallize (freeze) these unwanted cells in dedicated areas by using cryolipolysis technology.. When these fat cells melt they go to apoptosis (start to die) which causes the fat inside them to convert into lipids, which in return are removed from the body via normal metabolism. Since this is slow, gradual process the released lipids do not create stress on liver or other normal bodily functions. The destroyed fat cells do no regenerate, which helps to maintain the achieved results. After fat cells are exposed to sub zero temperatures for a prolonged period of time, they freeze and crystallize like we can see in the picture on the left. Freezing causes apoptosis of the fat cells, in other words they die and their structure "collapses" causing the smaller fat particles - the lipids - to dissolve into normal metabolic circulation. In this form, liver will turn the lipids into energy which decreases the appetite and at the same time removes and reduces the fat content of the body. Coolsculpting cryolipolysis body sculpting coolsculpting cellulite removal zeltiq coolsculpting lipolaser Coolsculpting Cavislim CET multipolar RF TAG: #Coolsculpting, #cryolipolysis body sculpting, #criolipolisis body sliming machine, #coolsculpting body sculpting system, #crotherapy slimming machine, #coolsculpting cellulite removal, #zeltiq coolsculpting lipolaser, #Coolsculpting Cavislim CET multipolar RF, #cryolipolysis Vacuum cavilsiming/cet rf, #coolshape cryolipolysis slimming machine
More Products
|