HydraFacial Oxygen therapy, Cryolipolysis, Pressotherapy Manufacturer
Search

Lumenis Cavitation RF Lypolysis Slimming Machine

Lumenis Cavitation  RF Lypolysis Slimming MachineLumenis Cavitation  RF Lypolysis Slimming MachineLumenis Cavitation  RF Lypolysis Slimming Machine
Lumenis Cavitation  RF Lypolysis Slimming Machine
  • Product:
    Lumenis Cavitation RF Lypolysis Slimming Machine

  • Model Number:
    BR108

     


    Learn more about products detailed description, pricing and service, Please send mail to us!

    Send Inquiry Back
Description:

 Technology Parameters

RF frequency

5MHz

RF level

1-30J/cm2

Cavitation frequency

40kHz 

Cavitation Power

50W/cm2 (max) 

Power of machine

150W

Touch screen

8 inch screen

Diode laser lights

650NM-660nm

Diode laser power

100MW Max

Voltage

220V /50Hz; AC110V/60Hz 

NW./GW

7KGS/13KGS

Packaging size

50cm*48cm*36cm

 

 Technology Parameters



















































RF frequency



5MHz



RF level



1-30J/cm2



Cavitation frequency



40kHz 



Cavitation Power



50W/cm2 (max) 



Power of machine



150W



Touch screen



8 inch screen



Diode laser lights



650NM-660nm



Diode laser power



100MW Max



Voltage



220V /50Hz; AC110V/60Hz 



NW./GW



7KGS/13KGS



Packaging size



50cm*48cm*36cm



 




Instruction

Developed by Multi-Polar RF Technology which is an innovative system maximizing all the benefits of RF technology.


Rejuvenize Face: Is a new and revolutionary system of skin rejuvenation without surgery, ana esthesia and post-operative treatment.


Rejuvenize Body: Contours, shapes and slims the body by improving cellulite and reducing circumference in as few as 3 treatment sessions. It is the fastest and safest RF system on the market effective for treating all skin types. Offers a non-surgical, non-invasive and painless treatment with no downtime for Skin Tightening & Body Contouring Treatments


Difference between Multipolar bipolar and mono-polar Radio frequency Mono-polar RF heats tissue in the treated area rather deeply (usually up to 20 mm) and thus affects both The skin and subcutaneous fat.

Bipolar RF heats tissue in the treated area less deeply (usually up to 2-4 mm) and thus primarily affects the skin. The patterns of energy distribution also differ. Whether Simultaneous treatment with both types of RF is additive, synergistic or otherwise in not entirely clear And needs further research. The manufacturers of mono polar+bipolar devices believe that such Combination is synergistic and allows to reduce the required intensity of each and thus minimize side Effects and possibly increase effectiveness.

While Multipolar combines the electrodes for the mono polar and bipolar RF application in the same hand-piece. It also utilizes sophisticated control algorithms for optimizing the concurrent application of the two Types of RF as well as tailoring the output to a particular patient and treatment goal.

It can promote tissue metabolism, repel the cellulite, tighten the skin, strengthen the skin elasticity and so on. Its effect will last for a long time. At the meanwhile, it can enhance the muscle elasticity and improve the cell metabolism. It creates an effect like internal Explosion. It means that the expansion and compression of wave produce a lot of tiny space inside the liquid. The gas and vapour exist in these tiny space. In the compression cycle, supersonic wave impose a positive pressure on liquid molecule, whereas a negative pressure will be created through the expansion cycle. There is a cohesion effect inside the liquid or biological tissues. Inside the low-density lipocyte, the cohesive effects are comparatively weak. A negative pressure, which is relative low, can create tissue gaps easily. It is called as Cavitations in physics. The explosion effects inside and outside the cells will increase the molecular movements, so as to achieve an high energy state, then lead to the lipocyte cracking.


Cautions for Using 40KHz Cavitation Head

1.Applied enough gel on skin need treated.

2.Do not stay unmoved on any part of your body,do not stay on bones.

3.The treatment should be within 30 minutes.

4.There will be ultrasonic only when you step on the service brake

5. not allowed to be placed under the state of no-load to avoid the damage caused by high heat.

6.

total time for daily

while using 40K cavitation

explode work head.

Do

40K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive

or becomes unhealthy, the strength of the power should be adjusted down.


Features

Ø Mono Polar RF for body and facial

Ø Bipolar RF for for lip lines and eyebrow removal;

Ø Tripolar for Body

Ø Hexpolar with diode laser for body

Ø 40KHz Cavitation for Body Cellulite removal

Ø Facial reshape handle piece professional design for face lift and slimming;

Ø 8 inch touch screen with English and Spanish two Languages

Ø CE approved;

Ø Painless treatment focus RF energy at the correct position, compared to other radio frequency technology. uses low energy and high frequency, safe and effective

Ø Aim at the skin surface and deep location, using a complex method to control the different currents and energy, direct access to the different skin layers, the effect is visible

Ø Selectively targeting fatty tissue, to avoid heating other fat, to achieve the fastest treatment effect

 

 

 


Technology Parameters

RF frequency
 5MHz
 
RF level
 1-30J/cm2
 
Cavitation frequency
 40kHz
 
Cavitation Power
 50W/cm2 (max)
 
Power of machine
 150W
 
Touch screen
 8 inch screen
 
Diode laser lights
 650NM-660nm
 
Diode laser power
 100MW Max
 
Voltage
 220V /50Hz; AC110V/60Hz
 
NW./GW
 7KGS/13KGS
 
Packaging size
 50cm*48cm*36cm
 

 

Forbidden group

1.People with heart disease or high blood pressure, or

configured cardiac pacemaker.

2.Patients with acute inflammation, asthma, deep vein

thrombosis, thyratrons, cancer.

3.People with hemorrhagic disease, trauma or who is

bleeding.

4.Pregnant women

5.Medical Plastic parts, or parts with artificial in filling inside.

6.People with metal inside the body(include metallic tooth)

7.Patient with skin inflammation or with edema.

8.People with an abnormal immune system.

9.Numb or insensitive to heat.

Accessories list

1. Mainframe

2. Power supply line

3. user manual

4. Mono-polar RF handle piece

5. Bipolar RF handle piece

6. Tripolar RF handle piece

7. Hex Polar RF diode laser handle piece

8. 40KHz cavitation handle piece

9. Accessory Frame

10. Hexagonal Screws

11. Hexagon Wrench
 

beauty equipment    slimming machine    Vaccum dissolving fat    wrinkles removal